Features
- Single and Dual Connectors
- Parallel Charging
- All-One-Format - Easy to Install
- RFID Reader
- Credit Card Reader
- OCPP 1.6J Compliant
- FRU Onboard Diagnostics
- Option for Liquid Cooled Connectors
- Easy to Service
- CE Certified
Product Number | HST-300-400 |
Maximum Power | 300 kW |
Input Voltage || Frequency | 400VAC || 480V (3P + N + PE) || 50/60 Hz |
Output Voltage | 150 - 750 VDC |
Output current | 0 to 400A (200A | 250A Limited by Connector) |
Power factor | > 0.98 |
Efficiency | >94% at nominal output power |
Connectors | Dual CCS Or Dual GB/T |
Cyclic Charge Mode | CCS2 - 200 A || GB/T ℃ 250A |
Parallel Charge Mode (Optional) | 150 kW per Port |
Connector cable length | 5m |
Weight | 560kgs |
Dimensions (L x D x H) | 830mm x 1000mm x 2000mm |
Charging Protocol Standards |
Mode 4 - IEC-61851, ISO-15118, DIN 70121 Mode 4 - GB/T 18487 2015, GB/T 20234 2015, GB/T 27930 2015 |
Insulation (input ℃ output) | >2.5 kV |
Ingress Protection | IP54, IK10 |
Operating temperature | - 22 F to 131 F ( 30 C to 55 C ) |
Altitude | <2000m |
Working || Storage Humidity | ≤ 95% RH || ≤ 99% RH (Non-condensing) |
Display | 7’’ touch screen |
Communication Protocol | OCPP 1.6J |
Access Control | RFID: ISO/IEC 14443A/B || Credit Card - Optional |
Power Electronics Cooling | Air Cooled |
Regulatory Compliance | CE || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012 |
Communication | Ethernet Standard 4G || Wi Fi (Optional) |
Electrical Safety: GFCI | RCD 30 Ma Type A |
Electrical Safety: Surge Protection | 20 Ka |
Electrical Safety General | Over Voltage, Under Voltage, Over Current, Missing Ground |
Electrical Safety: Output Short | Output power disabled when output is short circuited |
Electrical Safety Temperature | Temperature Sensors @ Charge Coupler and Power Electronics |
Emergency Stop | Disables output power with emergency stop button |